AIR CONDITIONER REPAIR

Fast and reliable fix for your air conditioner in London, Ontario.

For more than 15 years, homeowners in London, Ontario, have trusted Plumbhouse with air conditioner installation, air conditioner maintenance and repair. With almost two decades of experience and a highly skilled team, you can count on us for all your air conditioning issues.

It is essential to keep your air conditioning unit in functioning order, especially during hot months. We know how vital it is to keep your home cool and comfortable, which is why our service professionals in London, Ontario, are qualified to tackle a wide range of problems with AC units.

Call us today (519) 453-4650 or fill a form to get a free air conditioner repair consultation.

air-conditioner-reapir-london-ontario

Signs that you need air conditioner repair in London, Ontario.

  • Your energy bills rise every month. If you notice an increase in your energy bills during the hot months, it might be a sign that your unit is not working as it should be.
  • AC won’t turn on or runs erratically. If your unit does not run smoothly, it takes more energy than it should because it continually reboots itself. It is also a sign of a bigger problem. The sooner you have a technician check it, the more likely you are to avoid a huge bill.
  • Unusual sounds or smells. This is a clear sign of an incorrectly working air conditioner. Generally, smell or sound appears only after one or several components are heavily damaged.
  • The air conditioner can’t keep up the temperature. Lack of temperature control is one of the first things that happen to your cooling system when something is not functioning properly inside your air conditioner unit.

Why choose Plumbhouse for air conditioner repair in London, Ontario?

When you look for an air conditioner repair service, it is crucial to look for a proven service record. Plumbhouse has been serving London, Ontario, for more than 15 years now. We have an A+ BBB rating and more than 25 reviews on Google with an average of 4.7, which proves that we are not a flight-by-night operation, and our expertise can be trusted.

Common air conditioner problems in London, Ontario

A/C does not turn on

Possible Problem Areas

  1. Bad Capacitor
  2. Bad Control Board

Possible Explanation

  1. All capacitors do not have a long lifespan. However, a dirty condenser coil can shorten it even further. A dirty air filter also harms the capacitor.
  2. The Control board s not sending power to the outside unit when a thermostat is calling for cooling.

Possible Solution

  1. Replace the capacitor
  2. Replace the control board

A-coil freezes over

Possible Problem Areas

  1. Low level of refrigerant

Possible Explanation

  1. AC is a permanently sealed system, meaning whatever freon is in there stays in there for a unit's life. So, if some refrigerant is missing, it guarantees that you have a leak somewhere.

Possible Solution

  1. You will need a technician’s help to locate the leak and determine the repair cost. Sometimes, you might get away with just adding some freon every season.

The water is leaking all over the furnace

Possible Problem Areas

  1. Plugged Condensate Drain

Possible Explanation

  1. Either the hose that comes from the drain fitting from the AC evaporator coil on top of the furnace or the fitting is plugged up.

Possible Solution

  1. Either blow through condensate drain or take the hose and fitting off and clean it all out.

AC turns on together at the same time as heating

Possible Problem Areas

  1. Plugged Condensate Drain

Possible Explanation

  1. The Control board s not sending power to the outside unit when a thermostat is calling for cooling.

Possible Solution

  1. Replace the control board

AC blows out only hot air

Possible Problem Areas

  1. Burnt-out condenser fan motor

Possible Explanation

  1. The electrical surge or constant overheating can be the reason.

Possible Solution

  1. Replace the motor and the capacitor

You can sense a burnt electrical smell

Possible Problem Areas

  1. Burnt-out blower motor

Possible Explanation

  1. The electrical surge or constant overheating can be the reason.

Possible Solution

  1. Replace the blower motor and capacitor

A/C circuit breaker keeps tripping even after you reset it

Possible Problem Areas

  1. Compressor shorted to ground

Possible Explanation

  1. One of the compressor's wires was exposed and touched a metal element of the furnace.

Possible Solution

  1. Replace the compressor or the whole unit

Providing Residential and Commercial Plumbing, Heating & Electrical Services in London Ontario